Cluster Discovery¶
l8k discover inventories NVIDIA NICs and GPUs, groups nodes with compatible hardware, and writes an editable cluster-config.yaml. Fresh discovery resolves a profile; a --user-config refresh preserves its non-hardware settings.
Requirements¶
- Kubernetes access through
--kubeconfig,$KUBECONFIG, or~/.kube/config. - At least one Ready, schedulable node with a discoverable NVIDIA or Mellanox NIC. BlueFields in zero-trust (
restricted) mode do not count because NIC Configuration Operator does not publishNicDeviceresources for them. - Image pull access on eligible nodes to the configured NIC Configuration Daemon image.
For a private registry, forward one or more pull secrets:
l8k discover \
--image-pull-secrets registry-credentials \
--save-cluster-config ./cluster-config.yaml
The --node-selector value seeds deployment selection; it does not limit which nodes run the discovery daemon. Discovery derives an exact selector for each discovered worker group. An explicit CLI override is still user intent and is checked against saved worker membership at deployment.
Before waiting for NicDevice resources, Launch Kit checks BlueField trust
mode with mlxprivhost. A restricted BlueField is excluded from the wait set.
If the same node has another non-restricted NVIDIA NIC, that node remains in
the wait set and its published devices are discovered normally. A failed or
unrecognized trust query is treated as non-restricted, matching NIC
Configuration Operator behavior.
Run discovery¶
Discovery is self-contained. It does not require Node Feature Discovery (NFD) or a pre-installed Network Operator.
The temporary discovery daemon requests 64 MiB of memory and has a 512 MiB limit to accommodate hardware probes on nodes with large PCI inventories.
For Spectrum-X, discovery also saves the platform- and mode-specific desired
interface prefixes in clusterConfig[].spectrumX.interfaceNames. These do not
replace observed PF names. See Spectrum-X naming
for VR differences, custom settings and regeneration behavior.
Review saved inventory¶
Open cluster-config.yaml before generation. Confirm the intended workers and
source groups, east-west PF PCI addresses and rails, any north-south devices,
the chosen profile and release, and the node labels used for later selection.
Check the proposed network and driver settings against the site's approved
inputs in Plan your deployment.
Discovery does not prove that a subnet or maintenance budget is safe for the
site. Correct the editable source config before generation if needed.
If a worker is missing, check its readiness, image pull, discovery pod,
NicDevice publication, and zero-trust status. See Troubleshooting.
How Discovery Works¶
- Selects Kubernetes nodes that are Ready and schedulable.
- Prepares the private
nvidia-k8s-launch-kitnamespace. - Creates the NIC Configuration Operator CRDs only when they are missing.
- Runs a temporary NIC Configuration Daemon on the eligible nodes.
- Detects nodes with NVIDIA NICs through a PCI vendor
0x15b3sysfs probe and excludes BlueFields whose host trust level isrestricted. - Reads the published
NicDeviceresources and probes GPU, NIC, fabric, NUMA, and rail data. It does not walk kernel-module holder graphs. - Groups nodes, writes Launch Kit node labels, and saves the result. Fresh discovery resolves profile settings; with
--user-config,clusterConfig,discoveredSecondaryNetwork, anddiscoveredDocaHostare replaced. - Deletes the temporary namespace and cluster-scoped bootstrap RBAC. The CRDs remain installed.
The bootstrap namespace is fixed. --network-operator-namespace is accepted for compatibility but ignored by discovery.
Discovery reports each confirmed host-restricted BlueField PCI function with its
node and PCI address in normal CLI output, before deleting the bootstrap namespace.
The NIC-probe summary logs restrictedDevicesSkipped; this counts PCI functions,
not physical cards, separately from northSouthPFsFiltered (published devices
removed during group classification). Mixed nodes are scanned fully, so a usable
ConnectX does not hide a restricted BlueField later in PCI order. Restricted devices
remain absent from the saved configuration because the daemon does not publish them.
A failed or unrecognized trust query is not evidence of restriction and is not counted.
If the scan fails after verifying a usable NIC, the node remains eligible and a
warning marks exclusion reporting as incomplete. Read-only publisher eligibility
probes retain their early-exit behavior and do not collect this full inventory.
Hardware And GPU Topology¶
For each NIC, discovery records the device ID, PCI address, RDMA device, network interface, VPD identifiers, model, traffic direction, and rail. GPU and host details use layered sources:
- Existing
nvidia.com/gpu.machineandnvidia.com/gpu.productnode labels. - DMI data from the temporary daemon and GPU product observations from the same-node GPU sources described below.
- Sysfs PCI data and the embedded NVIDIA subset of
pci.idswhennvidia-smiis unavailable.
When GPU product labels are absent, each worker resolves its own nvidia-smi
or sysfs product before group aggregation. A product is saved only when all
workers agree. Missing or conflicting products leave gpuType unset with a
warning, so exact GPU-specific preset lookup is skipped; a representative
worker's fallback never replaces a known disagreement.
The same batched sysfs probe adds the NUMA node and reads current PF MAC
addresses transiently. Discovery mounts the host's /etc read-only and checks
worker nodes until it finds a match or has a conclusive observation for each.
If any NVIDIA PF matches a netplan
match.macaddress plus non-empty set-name rule, the group has
netplanManaged: true. If no match is found but a worker's observation is
unavailable or incomplete, the group has netplanManagementUnknown: true and
discovery warns. A readable host /etc with no netplan directory, or a complete
readable configuration with no MAC-based set-name rules, is a verified
negative and does not require PF MACs. When a MAC-based set-name rule exists,
an unreadable expected PF MAC also leaves the result unknown. Neither flag
persists host-unique MAC addresses. If l8k generate would emit a
NicInterfaceNameTemplate for a group with netplanManaged: true, it returns a
validation error because the confirmed netplan naming rule can conflict with
NCO naming. Remove the affected set-name stanzas and re-run discovery before
retrying generation. For netplanManagementUnknown: true without a confirmed
match, generation displays a warning in text and JSON output and continues.
Review the host netplan configuration and re-run discovery to resolve the
warning; do not clear the field manually. Re-run discovery for
configs created before netplanManagementUnknown was available.
GPU product and topology probing first tries a runtime-injected nvidia-smi
in the NIC daemon, then its legacy /host/usr/bin/nvidia-smi path when the
local observation is unavailable. If both observations are unavailable, discovery
selects the Ready main container of a same-node GPU Operator
gpu-feature-discovery DaemonSet, checking its owner UID and actual host /sys
mount. It rejects ambiguous sources and observations spanning a pod replacement
or container restart. Normal discovery looks up GFD across namespaces; that
fallback needs pod-list/read, DaemonSet-read, and pods/exec permissions.
It never injects a runtime class, allocates GPUs, or creates GPU probe pods.
Existing GPU runtime setup remains the cluster owner's responsibility.
The GPU query must cover an independently enumerated physical GPU PCI set from the NIC daemon's host sysfs, and its indices must match the complete matrix. Restricted or unresolvable MIG/vGPU views are unavailable topology. Missing GPU labels are not proof of a CPU-only node: unlabeled host-driver nodes retain the local product probe. Only a complete zero-GPU host enumeration without conflicting GPU labels permits skipping GPU probing.
Connected GPU, GPU PCI address and proximity are saved only when every worker and raw sibling PF represented by a retained PF agrees. NIC names are resolved by node and PCI; representative RDMA aliases are not reused across workers. Collapsed siblings must share a nearest GPU at the same proximity; overlapping nearest-GPU ties are compatible. GPU balancing then chooses once per retained rail on each node, so sibling planes do not consume extra assignments. Only complete relevant PF coverage permits a PIX-based traffic override and rail reassignment; physically dual-port BlueField-3 NICs stay north-south. Incomplete or conflicting results emit warnings, leave unavailable fields unset, and preserve hardware/preset fallback. Presets remain authoritative; their GPU index retains a measured PCI address only when all workers confirm it. VR NetworkBay rails are finalized afterward.
Collection uses up to four workers, with a 30-second budget per node and one bounded GFD lookup per invocation. Source failures do not retry. NIC PF/NUMA and netplan reads run in the NIC daemon. Check the selected GPU driver, toolkit and container image against your workload requirements. An accepted topology observation does not establish GPU or network deployment readiness.
VR NetworkBay rails¶
For platform vr, discovery requires eight east-west ASIC NICs in four
complete NetworkBay pairs on each worker. A compatible NIC Configuration
Daemon and served NicDevice CRD must expose status.networkBay.asic and
status.networkBay.peerPci. Each pair must have reciprocal peer PCI addresses
and one first ASIC (asic: 1) and one second ASIC (asic: 0).
Discovery creates missing CRDs but does not upgrade an installed CRD. If an
existing operator manages NicDevice, its owner must update the daemon and
CRD to versions that publish and retain NetworkBay status before VR discovery.
NetworkBays are numbered 1–4 by the ascending PCI address of their first ASIC. Discovery assigns the following zero-based rails:
| Rail | Members |
|---|---|
| 0 | NetworkBay 1 first ASIC + NetworkBay 2 second ASIC |
| 1 | NetworkBay 2 first ASIC + NetworkBay 1 second ASIC |
| 2 | NetworkBay 3 first ASIC + NetworkBay 4 second ASIC |
| 3 | NetworkBay 4 first ASIC + NetworkBay 3 second ASIC |
The mapping is finalized after GPU topology and preset enrichment and is also used by read-only discovery. Existing PF order is preserved; this mapping does not require a particular ASIC order within a rail. Missing, malformed or incomplete NetworkBay status, or differing mappings among workers in a group, stops discovery before inventory is saved. Non-VR rail assignment is unchanged.
With RA2.4/RA3.1 and ConnectX-9, fresh profile resolution defaults to hwplb
and eight planes. Explicit YAML/CLI settings take precedence; an existing-config
refresh preserves its profile settings as described below.
Profile Resolution¶
Fresh discovery persists a resolved profile block in cluster-config.yaml.
Values are resolved in this order:
- Hardware-derived values and Launch Kit defaults.
- Explicit CLI flags.
Fresh discovery fills missing profile fields:
deploymentdefaults tosriov.multiraildefaults totrue.routingdefaults todestination-based.fabricis persisted only when every discovered group has the same confirmed fabric.
When fabric probes disagree or cannot confirm a fabric, the saved profile.fabric remains empty. Set it explicitly during discovery or generation.
l8k discover \
--user-config ./site-config.yaml \
--fabric infiniband \
--deployment-type rdma_shared \
--multirail=false \
--save-cluster-config ./cluster-config.yaml
On a fresh run without --user-config, the example profile in the installed
reference configuration is ignored. With --user-config, discovery replaces
clusterConfig, discoveredSecondaryNetwork, and discoveredDocaHost, and clears
any previously generated discoveredDocaHostScope. It preserves every other loaded section and value,
including explicit false values, and then applies explicit CLI overrides.
Missing profile values are not filled during this refresh; supply them in the
file or through CLI flags if they are needed.
Host-installed DOCA-HOST¶
Discovery queries each retained inventory worker's host package database through
its existing privileged, host-PID NIC daemon (chroot /proc/1/root). It reads
doca-host using dpkg-query or RPM, preserving the full installed version in
discoveredDocaHost. It never uses the daemon container's package database.
A missing package is not-installed; failed exec, unsupported package managers,
partial installation, or unreadable metadata is unknown, with a warning.
At most four probes run concurrently. Each has a 30-second deadline and honors
command cancellation; diagnostics are emitted in node order after collection.
discoveredDocaHost:
- node: worker-a
status: installed
version: 3.5.0-041000-26.07-ubuntu2404
- node: worker-b
status: not-installed
The container driver defaults to enabled (docaDriver.enable: true). After
discovery, if every inventory worker has installed DOCA-HOST and the enable
choice is omitted or null, generation changes it to false, omitting
ofedDriver from the generated policies. Fresh discovery persists this resolved default;
a refresh preserves an omitted field so generation can derive it later.
Rediscovery also replaces invalid saved host observations, such as missing
package versions or invalid statuses, while preserving desired settings.
Generation and validation continue to reject invalid observations.
Explicit YAML true/false (including a selected reference file) and
generation's --enable-doca-driver override
remain authoritative. Absent or entirely unknown host evidence retains the
container-driver default of true.
Mixed installed and absent/unknown workers cannot share a safe automatic
choice under the global toggle. Discovery saves the evidence and warns, leaving
an omitted enable field unresolved. Generation requires an explicit
docaDriver.enable choice after the owner reviews host/container ownership.
This conservative decision uses the entire source inventory, including when
--groups or --gpu-type later filters rendering. Use a homogeneous source
inventory or explicitly select driver ownership for a filtered mixed inventory.
Topology presets do not replace host evidence. Generation captures the discovery
worker names and whether membership is complete in discoveredDocaHostScope
alongside the observations. This scope survives --for topology replacement
and the generated .l8k/resolved-config.yaml handoff, so later validation checks
the same original workers. Observations outside that scope remain excluded.
Repeated generation reuses the preserved scope; rediscovery clears it and
collects new inventory and observations. Presets contain topology only, and
preset-only inputs without discovery observations keep the default driver enabled.
Discovery warns when an installed DOCA release differs from the selected
Network Operator release SBOM; l8k validate rejects that mismatch even if the
container driver was explicitly enabled. The comparison uses the three-part
DOCA release (for example 3.5.0) extracted from the raw package version and
the catalog's SBOM-derived Mofed.version. Host package build identifiers and
OFED/container image build suffixes have different meanings and are not compared.
This does not qualify kernel modules, firmware, or a particular package build.
Validation checks the saved discovery snapshot, not current host package state;
rerun discovery after changing host packages or the selected release.
Library callers can opt in with WithReadOnlyDOCAHost(), alongside
WithReadOnlyRESTConfig(...). This uses only existing host-PID daemon pods and
requires pods/exec; default read-only calls acquire no additional probes.
Groups And Node Labels¶
Nodes with the same discovered PF fingerprint form a source group. Each group records its worker nodes, machine and GPU types, PFs, capabilities, dependent kernel modules, and deployment-time selector.
Discovery also writes up to two Launch Kit-owned labels:
| Label | Purpose |
|---|---|
nvidia.kubernetes-launch-kit.machine: <identifier> |
Selects one source hardware group using the same value persisted in clusterConfig[].identifier. |
nvidia.kubernetes-launch-kit.gpu: <gpuType> |
Selects compatible source groups that share a GPU type. |
The machine label and group identifier use the same lowercase value, shortened
when necessary. The GPU label preserves the discovered GPU name. Use the saved
clusterConfig[].identifier with --groups rather than constructing it yourself.
If the machine or GPU type cannot be resolved, a single group can have an empty
identifier; multiple groups use group-N. Every selected group still needs a
node selector that matches only its intended workers.
Before writing labels, discovery checks all proposed source identities and worker memberships for collisions. It publishes selectors only after labeling succeeds and a fresh list of every Node proves exact membership. Unresolved hardware identities require another proven selector, such as the hostname of a singleton; a broad PCI-vendor label is insufficient. Failed label writes or stale Launch Kit machine/GPU labels on excluded nodes stop discovery. Inspect and correct those labels deliberately before retrying; discovery does not remove unrelated labels. Completed patches may remain after an error, so retries revalidate live labels.
See Heterogeneous Clusters for group merging and targeted generation.
Fabric Detection¶
For east-west PFs with an RDMA device, discovery reads:
It falls back to the equivalent path under /host/sys. The configured link_layer is used even when the port is down, so a new cluster can be discovered before switch links are active.
A group receives linkType: Ethernet or linkType: InfiniBand when its contributing PFs agree. Failed or unavailable PF probes do not contribute. Conflicting recognized values leave the group unresolved.
The top-level profile fabric is defaulted only when every source group has a non-empty, unanimous linkType.
East-West And North-South NICs¶
Launch Kit generates networking resources from east-west NICs:
- BlueField-3 NICs whose VPD model identifies two physical ports (
dual-portor2-port) are classified as north-south, including whenNicDevice.status.dpuis false or their SKU is absent from the built-in DPU list. Multiple PCI functions alone do not establish physical port count; single-port multi-plane SuperNICs continue to use the existing classification rules. - A group containing only north-south NICs is omitted from
cluster-config.yaml. - In a mixed group, north-south PFs remain visible in the inventory but are not rendered into networking manifests.
This prevents out-of-band or DPU-facing NICs from consuming rail and NV-IPAM allocations intended for the workload fabric.
Rail Collapsing¶
By default, --collapse-nic-rails=true records one rail per physical NIC. Multi-plane PFs on one physical port collapse to the master PF, while a model explicitly identified as dual-port keeps one rail per port.
Use one rail per PF when your deployment requires that layout:
A collapsed live topology might no longer exactly match a preset that describes every PF. In that case, discovery keeps the live classification and reports the preset deviation.
Driver Module Safety¶
Launch Kit no longer walks /sys/module/*/holders/ during discovery. That probe could consume excessive memory on large nodes, and the generated driver policy now enables both unload controls by default:
docaDriver:
unloadStorageModules: true
unloadThirdPartyRDMAModules: true
skipPreflightChecks: false
# Advanced users only. Values override generated driver env by name.
# env:
# - name: THIRD_PARTY_RDMA_MODULES
# value: "nvidia_peermem"
The per-group storageModules and thirdPartyRDMAModules fields remain available for explicit site input and safety warnings. Review running storage and RDMA workloads before allowing the driver container to unload dependent modules.
Set skipPreflightChecks: true only when the module state is managed and verified outside Launch Kit.
Use docaDriver.env only for low-level driver settings that Launch Kit does
not model. Entries are forwarded through the generated NicClusterPolicy or
NicNodePolicy, override generated environment variables with the same name,
and can prevent the driver from reloading if misconfigured.
Topology Presets¶
After resolving each group's machineType and gpuType, discovery searches the local preset catalog for an exact match. A match can replace heuristic traffic, rail, NUMA, and GPU-affinity assignments with the certified topology.
There is no machine-only or any-GPU fallback. If no exact pair matches, discovery keeps the hardware-derived topology.
Preserve Bootstrap Resources¶
Discovery waits up to five minutes for daemon pods. It can proceed with the Ready pods when other daemon pods are on nodes that are not Ready, or when the wait timeout expires while the command is still active. Cancellation or a command deadline stops discovery and reports the reason. Discovery stops if no daemon pod becomes Ready.
Keep the namespace when investigating image pulls, scheduling, or daemon startup:
l8k discover \
--keep-namespace \
--save-cluster-config ./cluster-config.yaml
kubectl get pods,events -n nvidia-k8s-launch-kit
kubectl describe pod -n nvidia-k8s-launch-kit <pod-name>
kubectl logs -n nvidia-k8s-launch-kit <pod-name>
Before each run, Launch Kit removes stale bootstrap workloads and NicDevice resources from an interrupted prior run.
Debug Logging¶
l8k discover \
--log-level debug \
--log-file ./discovery.log \
--save-cluster-config ./cluster-config.yaml
Debug logs include node eligibility, sysfs NIC and BlueField trust probing, machine/GPU source selection, GPU topology, fabric reads, PF traffic classification, preset matching, rail collapsing, hardware fingerprints, and label writes. Summary counts remain visible at info level.
Saved Configuration¶
If --save-cluster-config is omitted, discovery rewrites the --user-config
file or creates cluster-config.yaml in the current directory. For a user
config refresh, only clusterConfig, discoveredSecondaryNetwork, discoveredDocaHost,
previously generated discoveredDocaHostScope, and explicit CLI overrides change. Source
comments are retained where possible, and a generated-file banner identifies
the discovery output.
Review the saved profile and clusterConfig sections before generation:
Platform networking observations¶
Both ordinary and read-only discovery inspect known API-visible Multus and
reference CNI plugin installers and save discoveredSecondaryNetwork. This
adds cluster-wide DaemonSet list reads and NCP GETs for candidate controller
references, without pods/exec or resource mutation. If optional inspection is
denied or unavailable, hardware inventory is still saved with unavailable
evidence; cancellation remains an error. Fresh and user-config refresh preserve
desired component policies separately. Auto generation rejects ambiguous or
unavailable evidence rather than treating failed inspection as permission to
install. Review secondary-network ownership
before selecting explicit managed/external policy. Unsupported or host-only
installers can remain undetected; Multus detection does not imply plugin-suite
presence.
Independent DPF inventory¶