Cluster Discovery

l8k discover inventories NVIDIA NICs and GPUs, groups nodes with compatible hardware, and writes an editable cluster-config.yaml. Fresh discovery resolves a profile; a --user-config refresh preserves its non-hardware settings.

Requirements

  • Kubernetes access through --kubeconfig, $KUBECONFIG, or ~/.kube/config.
  • At least one Ready, schedulable node with a discoverable NVIDIA or Mellanox NIC. BlueFields in zero-trust (restricted) mode do not count because NIC Configuration Operator does not publish NicDevice resources for them.
  • Image pull access on eligible nodes to the configured NIC Configuration Daemon image.

For a private registry, forward one or more pull secrets:

l8k discover \
  --image-pull-secrets registry-credentials \
  --save-cluster-config ./cluster-config.yaml

The --node-selector value seeds deployment selection; it does not limit which nodes run the discovery daemon. Discovery derives an exact selector for each discovered worker group. An explicit CLI override is still user intent and is checked against saved worker membership at deployment.

Before waiting for NicDevice resources, Launch Kit checks BlueField trust mode with mlxprivhost. A restricted BlueField is excluded from the wait set. If the same node has another non-restricted NVIDIA NIC, that node remains in the wait set and its published devices are discovered normally. A failed or unrecognized trust query is treated as non-restricted, matching NIC Configuration Operator behavior.

Run discovery

l8k discover \
  --kubeconfig "$KUBECONFIG" \
  --save-cluster-config ./cluster-config.yaml

Discovery is self-contained. It does not require Node Feature Discovery (NFD) or a pre-installed Network Operator.

Read-only library discovery

Library consumers that only need the inventory from an already-running NIC Configuration Daemon can call networkoperatorplugin.DiscoverReadOnly. The function reads the existing daemon pods, nodes, and NicDevice resources and returns a LaunchKitConfig without creating, patching, or deleting Kubernetes resources. It locates the existing daemon by its DaemonSet owner in the configured Network Operator namespace when WithReadOnlyNetworkOperatorNamespace is provided. Without that option, it checks the standard Network Operator and Launch Kit namespaces, preferring a usable Network Operator daemon when both installations are present. It returns networkoperatorplugin.ErrNotInstalled when the discovery daemon is not already running. With the configured-namespace option, callers need pod read access only in that namespace; otherwise they need pod-list access in all fallback namespaces. Both paths need cluster-scoped read access to nodes and all-namespaces read permission for the namespaced NicDevice resources. Use discovery.Discover when the caller is responsible for bootstrapping the temporary daemon.

The function does not use node labels to guess whether a daemon node can publish a NicDevice. If every Ready daemon node already has a device, no pod execution is needed. If any device is missing, pass networkoperatorplugin.WithReadOnlyRESTConfig with the REST config for the cluster. The function then runs the existing read-only NIC and BlueField trust probe in that node's daemon pod. It excludes nodes with no discoverable NIC or only restricted BlueFields, and reports a missing device for a verified NIC publisher. It returns inspection and permission errors instead of treating them as absent hardware. This fallback needs pods/exec permission in the daemon namespace.

Without a REST config, discovery returns an error by default. A caller that accepts an incomplete inventory can opt in with networkoperatorplugin.WithReadOnlyAssumeUnverifiedExcluded(). Ready daemon nodes without a NicDevice are then excluded and a warning reports that their publisher status is unverified. This option does not suppress errors from a probe attempted with a REST config. At least one NicDevice on a Ready daemon node is still required to construct an inventory.

For optional fabric enrichment, pass both networkoperatorplugin.WithReadOnlyRESTConfig(restConfig) and networkoperatorplugin.WithReadOnlyFabricDiscovery(). This explicitly permits read-only execs in the existing daemon pods and needs pods/exec permission in the selected daemon namespace. Supplying only a REST config retains the existing publisher-verification behavior and does not enable fabric probes. The fabric option without a REST config fails before cluster reads.

Fabric enrichment checks every selected worker and east-west PF, including sibling PFs represented by a collapsed rail. One batched command per worker confirms PCI-local RDMA names, enumerates all ports and reads their configured link_layer. Only complete, unanimous observations set a group's linkType; partial, denied, unreadable or conflicting observations leave it unknown with diagnostics. Link state and subnet-manager presence do not gate fabric detection. An InfiniBand PF without a netdev gets a separate IPoIB host-provisioning warning.

Normal discovery uses the same all-worker fabric check. Collection allows four concurrent workers with a ten-second deadline per worker and no timeout retry. Its optional worst-case budget is approximately ceil(selected workers / 4) * 10s plus API/dispatch overhead, capped by the caller's deadline. Internal probe failures leave fabric unknown; caller cancellation or deadline returns an error. Neither optional enrichment nor partial-inventory opt-in suppresses publisher inspection errors when REST credentials are supplied. These observations prove coverage of a successfully enumerated sysfs snapshot, not absent kernel hardware or deployment readiness. No host modules, node labels or Kubernetes resources are changed by read-only discovery.

GPU product/topology enrichment is separately opt-in: networkoperatorplugin.WithReadOnlyGPUTopology("gpu-operator") requires the actual GPU Operator namespace and WithReadOnlyRESTConfig(restConfig). Default calls and REST-only calls do not acquire GPU probes. This option reads host PCI identities in existing NIC daemon pods and tries nvidia-smi there, then uses a verified same-node GPU Operator gpu-feature-discovery container when necessary. It does not run the netplan workflow or modify either daemon. Callers need pod read/exec access in both namespaces and DaemonSet read access in the GPU Operator namespace. Missing namespace or REST credentials fails before cluster reads. Optional failures leave unavailable GPU fields unset; caller cancellation remains an error. Supply and consume a pkg/ui context sink to receive these warnings; the library's default sink is silent.

Review saved inventory

Open cluster-config.yaml before generation. Confirm the intended workers and source groups, east-west PF PCI addresses and rails, any north-south devices, the chosen profile and release, and the node labels used for later selection. Check the proposed network and driver settings against the site's approved inputs in Plan your deployment. Discovery does not prove that a subnet or maintenance budget is safe for the site. Correct the editable source config before generation if needed.

If a worker is missing, check its readiness, image pull, discovery pod, NicDevice publication, and zero-trust status. See Troubleshooting.

How Discovery Works

  1. Selects Kubernetes nodes that are Ready and schedulable.
  2. Prepares the private nvidia-k8s-launch-kit namespace.
  3. Creates the NIC Configuration Operator CRDs only when they are missing.
  4. Runs a temporary NIC Configuration Daemon on the eligible nodes.
  5. Detects nodes with NVIDIA NICs through a PCI vendor 0x15b3 sysfs probe and excludes BlueFields whose host trust level is restricted.
  6. Reads the published NicDevice resources and probes GPU, NIC, fabric, NUMA, and rail data. It does not walk kernel-module holder graphs.
  7. Groups nodes, writes Launch Kit node labels, and saves the result. Fresh discovery resolves profile settings; with --user-config, clusterConfig and discoveredSecondaryNetwork are replaced.
  8. Deletes the temporary namespace and cluster-scoped bootstrap RBAC. The CRDs remain installed.

The bootstrap namespace is fixed. --network-operator-namespace is accepted for compatibility but ignored by discovery.

Discovery reports each confirmed host-restricted BlueField PCI function with its node and PCI address in normal CLI output, before deleting the bootstrap namespace. The NIC-probe summary logs restrictedDevicesSkipped; this counts PCI functions, not physical cards, separately from northSouthPFsFiltered (published devices removed during group classification). Mixed nodes are scanned fully, so a usable ConnectX does not hide a restricted BlueField later in PCI order. Restricted devices remain absent from the saved configuration because the daemon does not publish them. A failed or unrecognized trust query is not evidence of restriction and is not counted. If the scan fails after verifying a usable NIC, the node remains eligible and a warning marks exclusion reporting as incomplete. Read-only publisher eligibility probes retain their early-exit behavior and do not collect this full inventory.

Hardware And GPU Topology

For each NIC, discovery records the device ID, PCI address, RDMA device, network interface, VPD identifiers, model, traffic direction, and rail. GPU and host details use layered sources:

  1. Existing nvidia.com/gpu.machine and nvidia.com/gpu.product node labels.
  2. DMI data from the temporary daemon and GPU product observations from the same-node GPU sources described below.
  3. Sysfs PCI data and the embedded NVIDIA subset of pci.ids when nvidia-smi is unavailable.

When GPU product labels are absent, each worker resolves its own nvidia-smi or sysfs product before group aggregation. A product is saved only when all workers agree. Missing or conflicting products leave gpuType unset with a warning, so exact GPU-specific preset lookup is skipped; a representative worker's fallback never replaces a known disagreement.

The same batched sysfs probe adds the NUMA node and reads current PF MAC addresses transiently. Discovery mounts the host's /etc read-only and checks worker nodes until it finds a match or has a conclusive observation for each. If any NVIDIA PF matches a netplan match.macaddress plus non-empty set-name rule, the group has netplanManaged: true. If no match is found but a worker's observation is unavailable or incomplete, the group has netplanManagementUnknown: true and discovery warns. A readable host /etc with no netplan directory, or a complete readable configuration with no MAC-based set-name rules, is a verified negative and does not require PF MACs. When a MAC-based set-name rule exists, an unreadable expected PF MAC also leaves the result unknown. Neither flag persists host-unique MAC addresses. If l8k generate would emit a NicInterfaceNameTemplate for a group that is managed or unknown, it returns a validation error rather than risking conflicting NCO naming rules. Resolve the discovery warning and re-run discovery, or remove the affected set-name stanzas and re-run discovery, before retrying generation. Re-run discovery for configs created before netplanManagementUnknown was available.

GPU product and topology probing first tries a runtime-injected nvidia-smi in the NIC daemon, then its legacy /host/usr/bin/nvidia-smi path when the local observation is unavailable. If both observations are unavailable, discovery selects the Ready main container of a same-node GPU Operator gpu-feature-discovery DaemonSet, checking its owner UID and actual host /sys mount. It rejects ambiguous sources and observations spanning a pod replacement or container restart. Normal discovery looks up GFD across namespaces; that fallback needs pod-list/read, DaemonSet-read, and pods/exec permissions. It never injects a runtime class, allocates GPUs, or creates GPU probe pods. Existing GPU runtime setup remains the cluster owner's responsibility.

The GPU query must cover an independently enumerated physical GPU PCI set from the NIC daemon's host sysfs, and its indices must match the complete matrix. Restricted or unresolvable MIG/vGPU views are unavailable topology. Missing GPU labels are not proof of a CPU-only node: unlabeled host-driver nodes retain the local product probe. Only a complete zero-GPU host enumeration without conflicting GPU labels permits skipping GPU probing.

Connected GPU, GPU PCI address and proximity are saved only when every worker and raw sibling PF represented by a retained PF agrees. NIC names are resolved by node and PCI; representative RDMA aliases are not reused across workers. Collapsed siblings must share a nearest GPU at the same proximity; overlapping nearest-GPU ties are compatible. GPU balancing then chooses once per retained rail on each node, so sibling planes do not consume extra assignments. Only complete relevant PF coverage permits a PIX-based traffic override and rail reassignment; physically dual-port BlueField-3 NICs stay north-south. Incomplete or conflicting results emit warnings, leave unavailable fields unset, and preserve hardware/preset fallback. Presets remain authoritative; their GPU index retains a measured PCI address only when all workers confirm it. VR NetworkBay rails are finalized afterward.

Collection uses up to four workers, with a 30-second budget per node and one bounded GFD lookup per invocation. Source failures do not retry. NIC PF/NUMA and netplan reads remain separate in the NIC daemon. Local tests verify source, coverage and failure handling; each actual driver/toolkit/image/runtime stack still needs live qualification. An accepted topology observation does not establish GPU or network deployment readiness.

VR NetworkBay rails

For platform vr, discovery requires eight east-west ASIC NICs in four complete NetworkBay pairs on each worker. A compatible NIC Configuration Daemon and served NicDevice CRD must expose status.networkBay.asic and status.networkBay.peerPci. Each pair must have reciprocal peer PCI addresses and one first ASIC (asic: 1) and one second ASIC (asic: 0). Discovery creates missing CRDs but does not upgrade an installed CRD. If an existing operator manages NicDevice, its owner must update the daemon and CRD to versions that publish and retain NetworkBay status before VR discovery.

NetworkBays are numbered 1–4 by the ascending PCI address of their first ASIC. Discovery assigns the following zero-based rails:

Rail Members
0 NetworkBay 1 first ASIC + NetworkBay 2 second ASIC
1 NetworkBay 2 first ASIC + NetworkBay 1 second ASIC
2 NetworkBay 3 first ASIC + NetworkBay 4 second ASIC
3 NetworkBay 4 first ASIC + NetworkBay 3 second ASIC

The mapping is finalized after GPU topology and preset enrichment and is also used by read-only discovery. Existing PF order is preserved; this mapping does not require a particular ASIC order within a rail. Missing, malformed or incomplete NetworkBay status, or differing mappings among workers in a group, stops discovery before inventory is saved. Non-VR rail assignment is unchanged.

With RA2.4/RA3.1 and ConnectX-9, fresh profile resolution defaults to hwplb and eight planes. Explicit YAML/CLI settings take precedence; an existing-config refresh preserves its profile settings as described below.

Profile Resolution

Fresh discovery persists a resolved profile block in cluster-config.yaml. Values are resolved in this order:

  1. Hardware-derived values and Launch Kit defaults.
  2. Explicit CLI flags.

Fresh discovery fills missing profile fields:

  • deployment defaults to sriov.
  • multirail defaults to true.
  • routing defaults to destination-based.
  • fabric is persisted only when every discovered group has the same confirmed fabric.

When fabric probes disagree or cannot confirm a fabric, the saved profile.fabric remains empty. Set it explicitly during discovery or generation.

l8k discover \
  --user-config ./site-config.yaml \
  --fabric infiniband \
  --deployment-type rdma_shared \
  --multirail=false \
  --save-cluster-config ./cluster-config.yaml

On a fresh run without --user-config, the example profile in the installed reference configuration is ignored. With --user-config, discovery replaces clusterConfig and discoveredSecondaryNetwork. It preserves every other loaded section and value, including explicit false values, and then applies explicit CLI overrides. Missing profile values are not filled during this refresh; supply them in the file or through CLI flags if they are needed.

Groups And Node Labels

Nodes with the same discovered PF fingerprint form a source group. Each group records its worker nodes, machine and GPU types, PFs, capabilities, dependent kernel modules, and deployment-time selector.

Discovery also writes up to two Launch Kit-owned labels:

Label Purpose
nvidia.kubernetes-launch-kit.machine: <identifier> Selects one source hardware group using the same value persisted in clusterConfig[].identifier.
nvidia.kubernetes-launch-kit.gpu: <gpuType> Selects compatible source groups that share a GPU type.

The machine label and group identifier share one lowercase, vendor-free value bounded to 30 bytes. The same normalization shortens common machine segments: ThinkSystem becomes ts and PowerEdge becomes pe. Long identities keep balanced machine/GPU prefixes plus a 6-character deterministic hash; unused prefix space moves to the longer component. GPU-only labels preserve the discovered case and NVIDIA segment, using the Kubernetes 63-byte limit and the existing 8-character shortening hash. If the machine or GPU type cannot be resolved, discovery preserves the unnamed identifier for a sole source, or uses group-N for multiple sources, and writes only labels it can construct. Either case still requires a proven exact selector.

Before writing labels, discovery checks all proposed source identities and worker memberships for collisions. It publishes selectors only after labeling succeeds and a fresh list of every Node proves exact membership. Unresolved hardware identities require another proven selector, such as the hostname of a singleton; a broad PCI-vendor label is insufficient. Failed label writes or stale Launch Kit machine/GPU labels on excluded nodes stop discovery. Inspect and correct those labels deliberately before retrying; discovery does not remove unrelated labels. Completed patches may remain after an error, so retries revalidate live labels.

See Heterogeneous Clusters for group merging and targeted generation.

Fabric Detection

For east-west PFs with an RDMA device, discovery reads:

/sys/class/infiniband/<rdma-device>/ports/1/link_layer

It falls back to the equivalent path under /host/sys. The configured link_layer is used even when the port is down, so a new cluster can be discovered before switch links are active.

A group receives linkType: Ethernet or linkType: InfiniBand when its contributing PFs agree. Failed or unavailable PF probes do not contribute. Conflicting recognized values leave the group unresolved.

The top-level profile fabric is defaulted only when every source group has a non-empty, unanimous linkType.

East-West And North-South NICs

Launch Kit generates networking resources from east-west NICs:

  • BlueField-3 NICs whose VPD model identifies two physical ports (dual-port or 2-port) are classified as north-south, including when NicDevice.status.dpu is false or their SKU is absent from the built-in DPU list. Multiple PCI functions alone do not establish physical port count; single-port multi-plane SuperNICs continue to use the existing classification rules.
  • A group containing only north-south NICs is omitted from cluster-config.yaml.
  • In a mixed group, north-south PFs remain visible in the inventory but are not rendered into networking manifests.

This prevents out-of-band or DPU-facing NICs from consuming rail and NV-IPAM allocations intended for the workload fabric.

Rail Collapsing

By default, --collapse-nic-rails=true records one rail per physical NIC. Multi-plane PFs on one physical port collapse to the master PF, while a model explicitly identified as dual-port keeps one rail per port.

Use one rail per PF for development or legacy configurations:

l8k discover \
  --collapse-nic-rails=false \
  --save-cluster-config ./cluster-config.yaml

A collapsed live topology might no longer exactly match a preset that describes every PF. In that case, discovery keeps the live classification and reports the preset deviation.

Driver Module Safety

Launch Kit no longer walks /sys/module/*/holders/ during discovery. That probe could consume excessive memory on large nodes, and the generated driver policy now enables both unload controls by default:

docaDriver:
  unloadStorageModules: true
  unloadThirdPartyRDMAModules: true
  skipPreflightChecks: false
  # Advanced users only. Values override generated driver env by name.
  # env:
  #   - name: THIRD_PARTY_RDMA_MODULES
  #     value: "nvidia_peermem"

The per-group storageModules and thirdPartyRDMAModules fields remain available for explicit site input and safety warnings. Review running storage and RDMA workloads before allowing the driver container to unload dependent modules.

Set skipPreflightChecks: true only when the module state is managed and verified outside Launch Kit.

Use docaDriver.env only for low-level driver settings that Launch Kit does not model. Entries are forwarded through the generated NicClusterPolicy or NicNodePolicy, override generated environment variables with the same name, and can prevent the driver from reloading if misconfigured.

Topology Presets

After resolving each group's machineType and gpuType, discovery searches the local preset catalog for an exact match. A match can replace heuristic traffic, rail, NUMA, and GPU-affinity assignments with the certified topology.

There is no machine-only or any-GPU fallback. If no exact pair matches, discovery keeps the hardware-derived topology.

Preserve Bootstrap Resources

Discovery waits up to five minutes for daemon pods. It can proceed with the Ready pods when other daemon pods are on nodes that are not Ready, or when the wait timeout expires while the caller's context is still active. If the caller's context is cancelled or reaches its deadline first, discovery returns that context error instead of continuing with an expired context. Discovery stops if no daemon pod becomes Ready.

Keep the namespace when investigating image pulls, scheduling, or daemon startup:

l8k discover \
  --keep-namespace \
  --save-cluster-config ./cluster-config.yaml

kubectl get pods,events -n nvidia-k8s-launch-kit
kubectl describe pod -n nvidia-k8s-launch-kit <pod-name>
kubectl logs -n nvidia-k8s-launch-kit <pod-name>

Before each run, Launch Kit removes stale bootstrap workloads and NicDevice resources from an interrupted prior run.

Debug Logging

l8k discover \
  --log-level debug \
  --log-file ./discovery.log \
  --save-cluster-config ./cluster-config.yaml

Debug logs include node eligibility, sysfs NIC and BlueField trust probing, machine/GPU source selection, GPU topology, fabric reads, PF traffic classification, preset matching, rail collapsing, hardware fingerprints, and label writes. Summary counts remain visible at info level.

Saved Configuration

If --save-cluster-config is omitted, discovery rewrites the --user-config file or creates cluster-config.yaml in the current directory. For a user config refresh, only clusterConfig, discoveredSecondaryNetwork, and explicit CLI overrides change. Source comments are retained where possible, and a generated-file banner identifies the discovery output.

Review the saved profile and clusterConfig sections before generation:

l8k generate \
  --user-config ./cluster-config.yaml \
  --save-deployment-files ./deployment

Platform networking observations

Both ordinary and read-only discovery inspect known API-visible Multus and reference CNI plugin installers and save discoveredSecondaryNetwork. This adds cluster-wide DaemonSet list reads and NCP GETs for candidate controller references, without pods/exec or resource mutation. If optional inspection is denied or unavailable, hardware inventory is still saved with unavailable evidence; cancellation remains an error. Fresh and user-config refresh preserve desired component policies separately. Auto generation rejects ambiguous or unavailable evidence rather than treating failed inspection as permission to install. Review secondary-network ownership before selecting explicit managed/external policy. Unsupported or host-only installers can remain undetected; Multus detection does not imply plugin-suite presence.