Render-Collision Separation#
Property |
Value |
|---|---|
Capability |
|
Owning tier |
Isaac |
Requirement |
|
Dependencies |
None |
Profile |
Pass condition#
Renderable prims with no enabled collision representation carry no inactive collision schema stack.
The validator inspects default- and render-purpose prims. It reports known collision schemas when PhysicsCollisionAPI is absent or collisionEnabled is false. A prim may intentionally serve both render and collision purposes; enabled colliders pass this check.
The input is one composed USD stage with a default prim. No original model, conversion history, or SimReady stamp is needed. An asset with no applicable content passes. A pass establishes this structural condition for the asset’s selected composition.
Validate and repair#
Run
simready-validate --profile Asset-Optimization --version 1.0.0 asset.usdand inspectOPT.003.If this check passes, leave the asset unchanged.
If it fails, run
remove_inactive_render_collision_schemason a staged copy.Save, reopen, and validate again. Report repair blockers with the affected prim and missing precondition.
The adapter removes only known inactive collision schema tokens and preserves unrelated schemas and properties. Active collider ownership, world transforms, and physics-material bindings must remain unchanged.
Instance-proxy candidates are reported by validation but block automatic repair. Repair their source prototype through an explicit authoring workflow. The adapter does not de-instance geometry or enable collision to make the check pass. It runs between body collapse and visual merge in the full profile.
The callback is independently available from
simready.foundation.tier_isaac.asset_handler_modules.isaac_optimization.
The installed simready.feature_adapters provider declares this capability as
the adapter’s exact output, selected by Asset-Optimization@1.0.0.
Validation evidence#
Tests compare authored and effective schemas, inactive schema stacks, and active collider paths, ownership, transforms, and physics materials. Actual simulator shape counts require an Isaac/PhysX measurement and are not a validation input.