FET004 Multibody#
Multibody physics: jointed assemblies articulate at their joints.
Overview#
This family discovers movable joints in an asset built from connected bodies and checks for relative body motion under configured simulation probes. The Core PhysX test requires at least one tested joint to cross its movement threshold; it does not require every discovered joint to respond or certify the complete articulation’s behavior.
What a Passing Family Means#
At least one tested joint produced relative body motion above the configured rotation or translation threshold. This does not establish that every joint works, every axis or limit is correct, or the assembly is ready for every downstream robot simulation. Review the individual joint metrics and videos.
Tests#
Test |
What It Checks |
Validates |
|---|---|---|
Discovers movable joints and verifies that at least one joint produces measurable relative motion between its connected bodies. |
FET004_Multibody, FET004_Multibody.PhysX, and FET004_Multibody.RobotPhysX (registered versions; RobotPhysX is deprecated compatibility) |
Relationship to the Feature#
These Core procedures validate the Standard and PhysX FET004 multibody
features using PhysX, including registered robot-specific PhysX variants.
Newton FET004 and RobotNewton features are exercised by the separate
joint_movement_newton procedure owned by the Newton tier.