payload-capacity#

Code

CN.005

Validator

PayloadCapacityChecker

Compatibility

open-usd

Tags

🔑

Summary#

Socket simready:mate:mechanical:maxPayload must be greater than or equal to the plug subtree mass. Incomplete mass on rigid bodies in that subtree warns rather than fails. Only jointed connections are checked; a compound has no joint to rate.

Description#

This check applies only to connections with realization = "jointed", where the socket and plug resolve to two distinct mate bodies (CN.006) and the authored joint (CN.009) carries the load.

Connections with realization = "compound" are skipped. There both sites resolve to the same rigid body, so the plug subtree is the compound itself and there is no joint to rate. CN.011 checks that compound’s aggregate mass instead. Cumulative load through a chain of nested assets is not modeled by this requirement.

Sum physics:mass from prims with PhysicsMassAPI in the plug site’s mate-body subtree. Do not read SR.003 customLayerData mass: that value lives on an asset’s root layer and does not compose across a reference.

Walk down from the mate body and stop at the first prim on each branch that authors physics:mass; that value stands for its whole subtree. Stopping is what keeps a compound aggregate from being added to the part masses beneath it. A jointed connection whose plug is itself a compound therefore contributes one aggregate, not the aggregate plus each fused part. This mirrors the RB.007 traversal, which stops descending at a body that owns its own mass, and it is the same walk CN.011 uses.

If every branch in the subtree yields an explicit mass, compare the sum to maxPayload and fail when the sum is greater. If any branch yields none, warn and skip the fail.

maxPayload and physics:mass are kilograms.

Why is it required?#

  • A legal swap is interface match plus mass within the socket rating.

  • Using composed PhysicsMassAPI is the only mass that is visible on the assembly stage.

Examples#

# Fail: socket maxPayload 5 kg, plug subtree mass 8 kg

# Warn: socket maxPayload 10 kg, one plug branch has no physics:mass

# Pass: socket maxPayload 10 kg, plug subtree mass 2.5 kg

# Pass: socket maxPayload 100 kg, plug is a compound body authoring 85.5 kg
# over three 28.5 kg pallets. The sum stops at the aggregate and is 85.5, not
# 85.5 + 3 x 28.5.

# Skipped: realization = "compound", both sites share one mate body

How to comply#

  1. Author positive maxPayload on the socket (MC.006).

  2. Author PhysicsMassAPI / physics:mass on plug rigid bodies so the assembly can sum them.