mechanical-interface#

Code

MC.004

Validator

MechanicalSitePropertiesChecker

Compatibility

open-usd

Tags

🔑

Summary#

Every mechanical mate site must author a non-empty simready:mate:mechanical:interface token.

Description#

interface is the catalog identity of the coupling: a published standard such as ISO 9409-1, a vendor product, or the interlock pattern of a stackable part. Compatibility on an assembly (CN.004) is exact string equality of this token on the socket and plug. Validators on a single asset only check that the token is present and non-empty; they do not check physical fit.

Sites in other domains are out of scope, as described in mechanical-role.

The token may imply electrical or pneumatic pass-through that is not modeled. Recommended form: ISO-9409-1-<designation> or <vendor>-<product>. The value set is open; a future warning-level prefix check is out of scope for this requirement.

Why is it required?#

  • A published asset must state what it fits without referring to any assembly.

  • Exact string equality is decidable without a tolerance policy.

Examples#

# Invalid: missing interface
def Xform "tool_plug_01"
{
    uniform token simready:mate:domain = "mechanical"
    uniform token simready:mate:role = "Plug"
}

# Invalid: empty token
def Xform "tool_plug_01"
{
    uniform token simready:mate:domain = "mechanical"
    uniform token simready:mate:role = "Plug"
    uniform token simready:mate:mechanical:interface = ""
}

# Valid
def Xform "tool_plug_01"
{
    uniform token simready:mate:domain = "mechanical"
    uniform token simready:mate:role = "Plug"
    uniform token simready:mate:mechanical:interface = "ISO-9409-1-50-4-M6"
}

How to comply#

  1. Author uniform token simready:mate:mechanical:interface with the published coupling designation.

  2. Use the same spelling on both the socket-bearing and plug-bearing assets that are meant to mate.